Data Collector Protocol

The connection between a data collector node and the gateway is via wifi and

Messages to the data collector node from the gateway are command messages. Messages from the data collection node to the gateway are data messages.

Commands

Command Token Parameters Description
Get Config GET <var> Get the specified configuration variable, * specifies all variables
Read Sensors RD <sensor_name> Directs the node to read one or more of its sensors and send the data once it is available, * = all sensors
Reboot/reset RS <na> Perform a self reset via power cycle if possible
Set Config SET <var>=<val> Set the specified configuration variable to the specified value