Data Collector Protocol
The connection between a data collector node and the gateway is via wifi and
Messages to the data collector node from the gateway are command messages. Messages from the data collection node to the gateway are data messages.
Commands
Command | Token | Parameters | Description |
---|---|---|---|
Get Config | GET | <var> | Get the specified configuration variable, * specifies all variables |
Read Sensors | RD | <sensor_name> | Directs the node to read one or more of its sensors and send the data once it is available, * = all sensors |
Reboot/reset | RS | <na> | Perform a self reset via power cycle if possible |
Set Config | SET | <var>=<val> | Set the specified configuration variable to the specified value |