data_collector_protocol
Differences
This shows you the differences between two versions of the page.
Next revision | Previous revision | ||
data_collector_protocol [2022/11/11 11:17] – created glen | data_collector_protocol [2022/11/12 13:11] (current) – [Data] glen | ||
---|---|---|---|
Line 2: | Line 2: | ||
The connection between a data collector node and the gateway is via wifi and | The connection between a data collector node and the gateway is via wifi and | ||
+ | |||
+ | |||
+ | |||
+ | Messages to the data collector node from the gateway are command messages. Messages from the data collection node to the gateway are data messages. | ||
===== Commands ===== | ===== Commands ===== | ||
+ | |||
+ | ^ Command ^ Token ^ Parameters ^ Description ^ | ||
+ | | Get Config | GET | <var> | Get the specified configuration variable, * specifies all variables | | ||
+ | | Read Sensors | RD | < | ||
+ | | Reboot/ | ||
+ | | Set Config | SET | < | ||
+ | |||
+ | ===== Data ===== | ||
+ | |||
+ | Data messages carry data form the collector node to the gateway node. The gateway node will interpret the contents and forward to the telemetry aggregator. Data node messages are comma delimited fields in a single row/record | ||
+ | |||
+ | * Data Node ID: Unique identifier of the data node, < | ||
+ | * Sensor ID: Unique within the data node (may be non-unique beyond the data node) | ||
+ | * Timestamp: <tbd> | ||
+ | * < | ||